Investigation of the Acoustic Performance of the Fire Extinguisher Ball Against Underground Fires

Document Type : tarvigi

Authors

1 School of Chemical Engineering -College of Engineering -University of Tehran

2 Research Institute of Engineering and Passive Defense, Imam Hossein University

Abstract

Preventing the spread of fire and reducing the associated risks, is a significant issue in passive defense. Underground places housing mechanical and electrical installations, tunnels, and underground infrastructures, are always at risk of fire, and timely information about fires in these places is doubly important. The use of fire extinguisher balls is one of the newest methods that has been proposed in order to deal with fire hazards in these places. These balls explode with the heat of the fire and sound a terrible alarm. In this study, the acoustic performance of these balls during the explosion in a hypothetical underground location was simulated and investigated by Comsol software and the parameters of acoustic pressure, total sound level and transmission loss during the explosion of the ball were studied. The results of the present study showed that at low to medium frequencies (below 900 Hz), the sound caused by the explosion of the ball would be well heard by those present in the surrounding area, which confirms the optimal sound performance of the ball in fire alarm and warning.

Keywords


Smiley face

  • L. Brauer, "Safety and health for engineers," John Wiley & Sons, 2016.
  • A. Purkiss and L.-Y. Li, "Fire safety engineering design of structures," CRC press, 2013.
  • Löwy, "Fire alarm: Reading Walter Benjamin's On the concept of history," Verso, 2005.
  • G. Il’ves, M. G. Zuev, and S. Y. Sokovnin, "Latest Design Factory Prices Automatic Ball Fire Extinguisher with Ce SGS," J Nanotech., vol. 2015, pp .417817, 2015.
  • Barua, M. S. S. Tanjim, A. N. Oishi, S. C. Das, M. A. Basar, and S. A. Rafi, "Design and Implementation of Fire Extinguishing Ball Thrower Quadcopter," in 2020 IEEE Region 10 Symposium (TENSYMP), pp. 1404-1407, 2020.
  • K. Goel, B. Singh, and J. Zhao, "Underground Infrastructures: Planning, Design, and Construction, " Butterworth-Heinemann, 2012.
  • Nordmark, "Fire and Life Safety for Underground Facilities: Present Status of Fire and Life Safety Principles Related to Underground Facilities: ITA Working Group 4, “subsurface planning”," Tunn. Undergr. Space Tech. , vol. 13, no. 3, pp. 217-269, 1998.
  • Bahrami, ''Investigation of the Variables Affecting the Fire Resistance of Buldings'', Pasive Defence Quarterly, vol. 12, no. 2, pp. 99-111, 2021 (In Persian).
  • Receive Date: 17 October 2021
  • Revise Date: 28 July 2022
  • Accept Date: 14 September 2022
  • Publish Date: 22 November 2022